Prepare and install the new wall sleeve according to the instructions below.
Ptac wall sleeve installation instructions.
The air conditioner will slide into the sleeve but is not flush with the wall.
The wall sleeve must be fastened securely before installing the air conditioner unit.
If the sleeve projects more than 8 into the room a sub base or other means of support must be used.
Wall sleeve installation 920 087 04 8 05 wall sleeve installation instructions pdxws note.
Tools required by.
Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve chassis and accessories.
Inches mm inches mm inches mm wall sleeve only 3 75 0 0 0 0 subbase kit 3 75 3 1 4 85 2 3 4 70.
To ensure proper airflow and filter removal it is recom mended installation of the wall sleeve be a minimum of 36 from the ceiling.
The wall sleeve be installed a minimum of 36 from the ceiling.
See the drain kit for internal actual installation instructions.
Consult a licensed contractor as needed.
There is a portion of the air conditioner which extends a few inches back into the room.
Wall case must be sealed caulked to outside wall on all four 4 sides.
Failure to install and maintain our product according to these instructions may void any product warranty.
16 24 28 and 31 deep cases are available for thicker walls.
When a drain kit is to be installed do so before top of wall sleeve installing the wall sleeve in the wall.
For new installs ensure the wall is properly framed to support the weight and dimensions of the wall sleeve and air conditioner.
For sunrooms and modular buildings adhere to their installation instructions for supporting and sealing sleeve to their frames.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
Installation guidelines for sealing ptac sleeves read these instructions completely before starting any installation.
Standard steel wall cases are 42 w 16 h 13 3 4 d.
All wall and window wall installations must provide for proper drainage.
All wall and window wall installations must provide for proper drainage.
Figure 4 minimum interior and exterior note.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
This information might be about you your preferences or your device and is mostly used to make the site work as you expect it to.
For sunrooms and modular buildings adhere to their installation instructions for supporting and sealing sleeve to their frames.
When you visit any website it may store or retrieve information on your browser mostly in the form of cookies.
Wall case should be sealed caulked to the inside wall on all four 4 sides.